    • SECURITY
    • FIRE EXTINGUISHING SYSTEM
    • HVAC SYSTEM
    • COMMUNICATIONS
    • SECURITY OF POWER SEPPLY
    • EQUIPMENT

    Our Data Centre is surrounded by a high-voltage fence line secured by external CCTV system throughout the whole perimeter. Remote-controlled lock check gates with an intercom device eliminate the possibility of unauthorized entry into the Data Centre perimeter. Access to the building and internal premises is carried out strictly after identification and verification of credentials. No one can access your equipment without your preliminary consent. High security level of our Data Centre is confirmed by the PCI-DSS certificate, which allows our Data Centre to be used for processing of operations with plastic cards.

    You can judge about the Data Centre’s reliability by its sophisticated fire extinguishing system. Argon-based system of very early smoke detection VESDA (Very Early Smoke Detection Apparatus) can immediately notify the fire extinguishing system in case of fire. The fire extinguishing system is connected to the ventilation system, which is switched off during fire extinguishing. The Data Centre walls are fireproof and withstand the effects of high temperatures for at least 180 minutes. In addition, a fire detection system is used, which is based on thermal detectors and optical detectors that detect changes in air currents. All systems are monitored 24/7/365 by a qualified support team.

    Our Data Centre has 2N redundancy cooling. The temperature of 24 °C (± 5 °C) and relative humidity of 50% (± 25%) are maintained constantly. Unique natural cooling solution is implemented in the Data Centre. This cooling method with low power consumption makes reasonable use of outdoor air, which has perfect temperature and humidity thanks to the temperate climate of the Netherlands.

    The Data Centre has excellent data transmission channels with all CIS countries. These channels typically provide higher speeds than channels between different CIS regions and within countries. This is achieved because the Data Centre is a major traffic exchange point, and the total number of uplinks and peerings exceeds 30. The largest operators that have direct channels with the Data Centre are: Level3, Telia Sonera, Global Crossing, Tata Telecommunications, Deutsche Telekom, Cogent and others. Total bandwidth is 4.5 Tbps. Perhaps, this Data Centre has the best communication capabilities in the world.

    APC battery room and 16 diesel generators (1540 kVA each) provide uninterrupted power supply for our Data Centre since 2007. 15 kW is typically supplied for one rack, while up to 25 kW can be supplied on request.

    We offer branded Hewlett Packard, IBM, Dell equipment only. When renting our servers, you do not have to worry about its technical condition.

    • SECURITY

      Our Data Centre is surrounded by a high-voltage fence line secured by external CCTV system throughout the whole perimeter. Remote-controlled lock check gates with an intercom device eliminate the possibility of unauthorized entry into the Data Centre perimeter. Access to the building and internal premises is carried out strictly after identification and verification of credentials. No one can access your equipment without your preliminary consent. High security level of our Data Centre is confirmed by the PCI-DSS certificate, which allows our Data Centre to be used for processing of operations with plastic cards.

    • FIRE EXTINGUISHING SYSTEM

      You can judge about the Data Centre’s reliability by its sophisticated fire extinguishing system. Argon-based system of very early smoke detection VESDA (Very Early Smoke Detection Apparatus) can immediately notify the fire extinguishing system in case of fire. The fire extinguishing system is connected to the ventilation system, which is switched off during fire extinguishing. The Data Centre walls are fireproof and withstand the effects of high temperatures for at least 180 minutes. In addition, a fire detection system is used, which is based on thermal detectors and optical detectors that detect changes in air currents. All systems are monitored 24/7/365 by a qualified support team.

    • HVAC SYSTEM

      Our Data Centre has 2N redundancy cooling. The temperature of 24 °C (± 5 °C) and relative humidity of 50% (± 25%) are maintained constantly. Unique natural cooling solution is implemented in the Data Centre. This cooling method with low power consumption makes reasonable use of outdoor air, which has perfect temperature and humidity thanks to the temperate climate of the Netherlands.

    • COMMUNICATIONS

      The Data Centre has excellent data transmission channels with all CIS countries. These channels typically provide higher speeds than channels between different CIS regions and within countries. This is achieved because the Data Centre is a major traffic exchange point, and the total number of uplinks and peerings exceeds 30. The largest operators that have direct channels with the Data Centre are: Level3, Telia Sonera, Global Crossing, Tata Telecommunications, Deutsche Telekom, Cogent and others. Total bandwidth is 4.5 Tbps. Perhaps, this Data Centre has the best communication capabilities in the world.

    • SECURITY OF POWER SEPPLY

      APC battery room and 16 diesel generators (1540 kVA each) provide uninterrupted power supply for our Data Centre since 2007. 15 kW is typically supplied for one rack, while up to 25 kW can be supplied on request.

    • EQUIPMENT

      We offer branded Hewlett Packard, IBM, Dell equipment only. When renting our servers, you do not have to worry about its technical condition.